RSS Feed

Posts Tagged ‘“drain’

Bathroom Cleaning Services

June 20, 2010 by stain remover expert No Comments »

bathroom cleaning services
Portland real estate investor Barry Menashe refuses to pay the fees of $ 50,400 the city in protest campers from downtown Menashe said he likes downtown Portland, but he will not continue to pay $ 4,000 per month for cleaning and security services that do not work. The Portland Business Alliance which manages the services, said he has tried to address concerns Menashe.
How To Clean Your Bathroom Cleaning Services Boston

 

Septic System Cleaning

January 22, 2010 by stain remover expert No Comments »

septic system cleaning

Pumping your septic tank

Pumps are typically either vacuum or centrifugal. Vacuum pumps, the system most commonly used by carriers of turbidity has the following advantages: Iiquid does not pass through the pump, which reduces wear, the pump is less likely to freeze, and the tank contents may be discharged under pressure. Vacuum pumps should be equipped with a water trap to prevent dispersion of aerosols. Because moves LIQ-uid through the pump, centrifugal pumps are more likely to clog and wear more readily from grit and debris. Centrifugal pumps are generally open-wheel or recessed-impeller for handling solids. Both types of centrifugal pumps have a suction lift up to approximately 27 ft (8 m). Some truck-mounted tanks are equipped with high-level automatic shutoff controls to prevent overfilling. Power Pump are generally at least 400 gal / min (1,500 Umin). The pipes shall be black rubber vacuum or synthetic material, with a minimum diameter 3 inches (8 cm). The pipes should also be drained, and capped to minimize spillage. Carriers generally carry less than 100 feet (30 meters) of hose. Discharge valves on the truck carrier should be drip tight, and a nipple discharge should accommodate a quick-disconnect coupling. Other equipment includes a device to break the layer of foam (eg, a long fork), the probe shovel soil, to locate the septic system and other tools to measure accumulations or perform other tasks or in the field. A squeegee and accessories stick vacuum must be made "the pumper, a monthly publication for industry waste carrier liquid, produces an annual directory of suppliers of equipment that is free with a subscription to the "pumper. to help clean up spills. Lime should also be available to apply to areas where sludge has been overthrown.

sludge dewatering systems mobile developed originally in Europe, are now available in the United States. Withthese systems, sludge is removed from the septic tank in a compartment on the truck; filtrate returned to the septic tank. Polymer or lime is added to the sludge during the transfer to a dewatering tank, where most solids. A sludge solids content of 15 to 20 per cent is achievable should the polymer and lime systems, respectively Mobile dewatering systems Offer: Lower transportation costs due to fewer trips to the disposal site, greater truck capacity, lower volumes of material requiring treatment and disposal. These benefits are best suited to areas with many septic tanks and long travel distances on the landfill site. The Disadvantages include more complex operational requirements and high costs of hardware investment.

After the septic tank been located and the access hatches exposed, the entry and exit baffles or tees are examined for problems such as damage, loose connections, and connection. Broken pipes or baffles should be replaced or repaired. If the fluid level in the tank is higher than the outlet pipe, this may indicate blockage in the outlet pipe or in the drainfield. Then the carpet foam is broken manually to facilitate pumping. Before this is done, the level of liquid in the septic tank is lowered as the first strike of the exit, which prevents the fat and the residue being washed into the drainfield. After the foam mat is broken, the contents of the tank are removed. Normally the suction pipe vacuum / suction air to a point where 1-2 inches (2.5 to 5 cm) of sludge remains on the bottom of the tank, which materialshould be left in the tank. Wash the inside of the tank is useless unless it is suspected a leak and the interior must be inspected for cracks, if an internal inspection is necessary, fresh air should be continuously blown into the tank during at least 10 minutes.

Move toxic gases or oxygen in the air. The inside can then be inspected from the surface with a lamp pocket. A septic tank should never be reached without testing the air for oxygen, lower explosive limit, and hydrogen sulfide. This is accomplished by using electronic gas sensors triple ', available from equipment suppliers industrial safety. Septic tanks are considered confined spaces and are subject to regulations issued by the confined space safety work
and Health Administration (1910.146 OSHA Standard). Anyone entering a septic tank should wear a safety harness connected to a winch aboveground. Two more workers should be on deck to help the inspector in case of problems. Your state or local agency responsible for health and Safety should be contacted about additional regulations concerning entry into confined spaces in their jurisdiction. In the case of a spill, sludge must be cleaned immediately. The hydrated lime should be sprinkled on the spill area, and a squeegee and a suction wand attached to the end of vacuum hose are useful tools for cleaning. For large spills, a second pumper truck may be necessary business with one truck should reach an agreement with another company for help in an emergency cleanup of spills.

Adding a chemical or biochemical agents from the septic tank, as disinfectants, microorganisms and enzymes, is discouraged. These formulations offer little or no benefit and may even be detrimental to the operation of the septic tank and drainfield. For example, agents that fat emulsify allow its discharge into the soil absorption system, where the emulsion may break at the soil surface and cause increased invasive the rate of clogging or pass through the soil into the groundwater. Other
agents are made of strong alkaline compounds that can pass through a tank and destroy the soil structure. The formulations contain the most harmful chlorinated hydrocarbons, which can pass through the reservoir and the soil to contaminate groundwater. Fortunately, many commercial products do not affect the performance of each of the tanks or systems soil. Even if none of the known benefits have been demonstrated to date, the possibility of a formulation effective in future can not be excluded.

[mage lang="en|fr|en" source="youtube"]Septic System Cleaning[/mage]